“The Right Control for Your Application.” 12095 NW 39 Street, Coral Springs, FL 33065-2516 Telephone: 954-346-4900; Fax: 954-346-3377 KB Electr
7Control Set for 230 VAC(Factory Setting)Control Set for 115 VACTABLE 3 – SETTING AC LINE VOLTAGEWITH JUMPER J2A and J2BFIG. 5 – MOTOR OUTPUT TORQUE v
8Control Set for 180 VDC(Factory Setting)Control Set for 90 VDCTABLE 4 – SETTING ARMATUREVOLTAGE WITH JUMPER J3For 230VAC line input, thearmature volt
91. Timed current limit "TCL": In this mode the drive will turn off after being in current limitfor a preset time. The time period is adju
10FIG. 8 – CONNECTION DIAGRAMFIG. 7A – CAPTIVE SCREWTIGHTENED IN CASEFIG. 7B – CAPTIVE SCREWENGAGED IN FRONT COVERIV. WIRING. Warning! Read Safet
11FIG. 10 – TACH-GENERATORCONNECTION DIAGRAMTABLE 8 – RELATIONSHIP of AC LINE INPUT AND MOTORVOLTAGE with J2 and J3 JUMPER POSITIONAC INPUT VOLTAGE J2
12FIG. 11 – REMOTEPOTENTIOMETERFIG. 12 – ANALOG VOLTAGEFIG. 13 – REMOTE START/STOP SWITCHFIG. 14 – INHIBIT CIRCUITNote: If the tach voltage is connec
13FIG. 15 – ENABLE CIRCUITV. FUSING.A. AC Line Fusing – Most electrical codes require that each ungrounded conductor containfusing. Separate branch c
14VII. TRIMPOT ADJUSTMENTS.The control contains trimpots, which have been factory adjusted for most applications. Figure1 page 3 illustrates the loca
152. Do not leave the motor in a locked condition for more than a few seconds sincearmature damage may occur.F. IR Compensation (IR) – The IR comp cir
16C. Signal Isolator (Model KBSI-240D, P/N 9431) – Signal isolation is required when aremote nonisolated analog signal is to be used. Provision is ma
See Page 2Note: Productillustration isshown withoptional Forward-Brake-Reverseand Run-Jogoptions.This control willnot operatewithout installingthe co
20FIG. 17 – CONNECTION DIAGRAMS FOR KBPC-240D WITH KBSI-240D SIGNAL ISOLATOR
21APRM®-PC (Electronic FWD-BRK-REV)FIG. 18 – INTERNAL CONNECTION DIAGRAM FIG. 19 – CONNECTION DIAGRAMS FOR AVAILABLE OPTIONS
X – LIMITED WARRANTYFor a period of 18 months from date of original purchase, KB will repair or replace withoutcharge devices which our examination pr
iiTABLE OF CONTENTSSection Pagei. KBPC-240D Simplified Operating Instructions ...1ii. Safety Warning ...
1i. KBPC-240D SIMPLIFIED OPERATING INSTRUCTIONSIMPORTANT – You must read these simplified operatinginstructions before you proceed. These instruct
2 ii. SAFETY WARNING! — PLEASE READ CAREFULLYThis product should be installed and serviced by a qualified technician, electrician or electricalmain
3FIG. 1 – CONTROL LAYOUT(Illustrates Factory Setting of Jumpers and Approximate Trimpot Settings)
4 INCHES [mm]FIG. 2 – MECHANICAL SPECIFICATIONSTMTM
5TABLE 1 – ELECTRICAL RATINGSModelInputVoltage(VAC)Max. ACCurrent(ARMS)Output Voltage(VDC)Max. DC OutputCurrent (ADC)Max.HP, (KW)KBPC-240D115 15.0 0 –
6FIG. 3 – MOTOR SPEED vs POTENTIOMETER ROTATION – [SPEED MODE]FIG. 4 – PRESET MOTOR SPEED vs MOTOR LOAD – [SPEED MODE]When Jumper J1 is placed in the