Kb-electronics KBAC-29 (1P) User Manual

Browse online or download User Manual for Software Kb-electronics KBAC-29 (1P). KB Electronics KBAC-29 (1P) User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 29
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MODEL KBAC-29 (1P) SUPPLEMENT
IMPORTANT: The KBAC Series Installation and Operation Manual (Part No. A40206) must be read
and understood before attempting to operate this drive. For further assistance, contact our sales
Department at 954-346-4900 or Toll Free at 800-221-6570 (outside Florida).
DESCRIPTION: Model KBAC-29 (1P) has been added to the KBDA Series of drives. This model is
designed to accept single-phase 208/230 Volts AC line input only. Table 3A, Table 4A, and Figure
8A, below, are additions to Table 3 (on page 10), Table 4 (on page 10), and Figure 8 (on page 14),
respectively, of the manual.
WARNING! HIGH VOLTAGE!
DISCONNECT MAIN POWER BEFORE MAKING CONNECTIONS TO THE DRIVE
TABLE 3A – GENERAL PERFORMANCE SPECIFICATIONS
Description Specification Factory Setting
Operating Temperature Range (°C / °F) 0 – 35 / 32 – 95 ──
Operating Humidity Range (% Relative, Non-Condensing) 0 – 95 ──
Storage Temperature Range (°C / °F) -25 – +85 / -13 – +185 ──
TABLE 4A – ELECTRICAL RATINGS
AC Line Input Output
Model
Part No.
(Gray / White
1
)
Volts AC
(50/60 Hz)
Phase
(Ф)
Maximum
Current
(Amps AC)
Fuse or
Circuit
Breaker
Rating
(Amps)
Voltage
Range
(Volts AC)
Maximum
Continuous
Load Current
2
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW))
KBAC-29
(1P)
10001 / 10002 208/230 1 20.5 25 0 – 208/230 9.0 3 (2.25)
Notes: 1. White FDA approved finish. 2. The drive is rated 9.0 Amps at 35 °C, maximum, and
derated to 8.3 Amps at 40 °C. For ambient temperatures above 40 °C, the drive is derated 2.5%
per °C.
FIGURE 8A – A LINE INPUT, MOTOR, AND GROUND CONNECTIONS
KB Electronics, Inc.
12095 NW 39th Street, Coral Springs, FL 33065-2516 (954) 346-4900 FAX (954) 346-3377
Outside Florida Call Toll Free (800) 221-6570 [email protected]
www.kbelectronics.com (A42047) – Rev. A00 – 3/22/2010
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1 - WARNING! HIGH VOLTAGE!

MODEL KBAC-29 (1P) SUPPLEMENT IMPORTANT: The KBAC Series Installation and Operation Manual (Part No. A40206) must be read and understood before atte

Page 2 - KBAC SERIES

Output Contacts:Run/Fault RelayStart/Stop Switch:Main Speed Potentiometer:Diagnostic LEDs:J4: 1X or up to 2XJ9: Normally Open or ClosedJ11: I t Overlo

Page 3

A B C D E10Description Specification Factory Setting115 Volt AC Line Input Voltage Operating Range (Volts AC) 115 (±15%) —208/230 Volt AC Line Input V

Page 4 - UL Notice

0.317.975.86Maximum Depth:1498.20 9.53208 2422.5364.40.258.852256.44* 1*2* 3*5.511295.061402X ∅11FIGURE 3 – MODEL KBAC-24D MECHANICAL SPECIFICATIONS (

Page 5 - AC LINEMOTOR

124 IMPORTANT APPLICATION INFORMATION4.1 MOTOR WITH EXTERNAL FAN COOLING – Most totally enclosed fan-cooled (TEFC) and open ven-tilated 3-phase AC ind

Page 6 - 2 SAFETY WARNING

5.1 AC LINE INPUT CONNECTION – Wirethe AC line input to Terminal Block TB1.GFCI Operation – Do not connectthis drive to an AC power sourcecontrolled b

Page 7 - 3 INTRODUCTION

14Model KBAC-29: Designed to accept single-phase (Terminals “L1”, “L2”) or 3-phase (Terminals “L1”,“L2”, “L3”) AC line input. Rated for 208/230 Volt A

Page 8

inside the drive. The switch assembly may beremoved if a liquidtight seal is used to coverthe hole in the front cover. After applyingpower to the driv

Page 9

16The Enable function is established bywiring a switch or contact in series withthe orange Main Speed Potentiometerlead which connects to Terminal “P2

Page 10 - FIGURE 2 – CONTROL LAYOUT

Using pliers, gently rock the female terminal back and forthwhile pulling it upward. See Figure 176.2 MOTOR HORSEPOWER SELECTION (J2) – Set Jumper J2t

Page 11 - TABLE 4 – ELECTRICAL RATINGS

186.5 BOOST MODE SELECTION (J6) –Jumper J6 is factory set to the “FIX”position for Fixed Boost. ForAdjustable Boost using the BOOSTTrimpot, set Jumper

Page 12

Installation & Operation ManualKBAC SERIESVariable Speed / Soft-Start AC Motor Drivewith Electronic Motor Overload Protection for Inverter Duty Mo

Page 13 - (100 CFM Min

7 MOUNTING INSTRUCTIONSIt is recommended that the drive be mountedvertically on a flat surface with adequateventilation. Leave enough room below thedr

Page 14 - 5 WIRING INSTRUCTIONS

20ChassisP3ChassisMachine Equipment or FrameAdjustable Frequency Drive(Main Power Disconnected)to AC Line InputsConnect Hi-PotL2L1P2P1Auxiliary Equipm

Page 15 - Model KBAC-29 Only

9 DRIVE OPERATION9.1 START-UP PROCEDURE – After the drive has been properly setup (jumpers and trimpots set to thedesired positions) and wiring comple

Page 16

2212 TRIMPOT ADJUSTMENTS The drive contains trimpots which are factory set for most applications.See Figure 2, on page 9, for the location of the trim

Page 17 - Output Contacts

12.4 DECELERATION (DECEL) – Sets the amount of time for themotor to decelerate from full speed to zero speed. The DECELTrimpot is factory set to 1.5 s

Page 18 - Installed

2412.8 BOOST (BOOST) – The drive is factory set for Fixed Boost (Jumper J6 set to the “FIX” position).When the drive is set for Adjustable Boost (Jump

Page 19 - VS. OUTPUT FREQUENCY

WARNING! To avoid motor winding overheating and failure,do not overboost the motor.Note: An unloaded motor with excessive boost will draw morecurrent

Page 21 - AC KILOVOLTS

– NOTES –27

Page 22 - 11 DIAGNOSTIC LEDS

LIMITED WARRANTYFor a period of 18 months from the date of original purchase, KB Electronics, Inc. will repair or replacewithout charge, devices which

Page 23 - 12 TRIMPOT ADJUSTMENTS

TABLE OF CONTENTSSection Page1 Quick-Start Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24

30 Minimum Speed Trimpot (MIN) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2231 Max

Page 25 - Motor Current (%)

4See Figure 1. Also see Section 4 - Important Application Information, on page 12.WARNING! Disconnect main power before making connections to the driv

Page 26 - (SPDT - Center Off)

Models KBAC-45, 48: Designed to accept 3-phase (Terminals “L1”, “L2”, “L3”) AC line input only.Rated for 400/460 Volt AC line input only. See Figure 8

Page 27 - – NOTES –

63 INTRODUCTIONThank you for purchasing the KBAC Adjustable Frequency Drive. KB Electronics, Inc. is committed toproviding total customer satisfaction

Page 28

• Start/Stop Switch – Provides electronic start and stop functions.• Barrier Terminal Block – Facilitates wiring of motor, AC line, and Run/Fault Rela

Page 29 - KB ELECTRONICS, INC

8Description1PC BoardDesignationKBAC-24D KBAC-27D KBAC-29 KBAC-45 KBAC-48AC Line Input Voltage (115, 230) J13 3— — —Motor Horsepower (see Table 4 - El