INSTALLATION AND OPERATION MANUAL
KBWA SERIES
HYBRID DRIVE™
Digital Drive with Analog Interface
KBWA-23D: NEMA 1 / IP20 (Vented) Enclosure
KBWA-22D, 21D, 2P6D, 2P3D: NEMA 1 / IP50 (Non Vented) Enclosure
Rated for 208 – 230 Volt 50 and 60 Hz
Subfractional thru 1/2 HP 3-Phase AC and PSC* Induction Motors
Operates from 115 and 208/230 Volt 50/60 Hz AC Line Input
Variable Speed / Soft Start
with Electronic Motor Overload Protection
Provision for
Forward-Stop-Reverse
Switch (supplied).
(See Sec. 6, on p. 18)
*Operation with
PSC Motors requires
factory programming.
RoHS
This Manual Covers Models KBWA-23D, 22D, 21D, 2P6D, 2P3D
SEE
SAFETY WARNING
ON PAGE 2
IMPORTANT
AC Line Input Voltage Setting: The drive is factory set for
208/230 Volt AC Line input. For 115 Volt AC Line input, see
Section 7.1, on page 19.
Motor Frequency Setting: The drive is factory set for 60 Hz
Motors. For 50 Hz Motors, see Section 4.1, on page 13.
Copyright © 2014
KB Electronics, Inc.
(see back cover)
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1

INSTALLATION AND OPERATION MANUAL KBWA SERIES HYBRID DRIVE™ Digital Drive with Analog Interface KBWA-23D: NEMA 1 / IP20 (Vented) Enclosure KBWA-22D,

Page 2

10 3 INTRODUCTION Thank you for purchasing the KBWA Series Hybrid Drive. KB Electronics, Inc. is committed to providing total customer satisfaction b

Page 3

11 3.1 STANDARD FEATURES  Model KBWA-23D: Housed in a NEMA 1 / IP20 vented enclosure.  Models KBWA-22D, 21D, 2P6D, 2P3D: Housed in a NEMA 1 / IP5

Page 4

12 3.3 PROTECTION FEATURES  Motor Overload (I2t) with RMS Current Limit: Provides motor overload protection which prevents motor burnout and elimina

Page 5

13 3.6 CUSTOMIZATION FOR OEMs  Custom Software: The drives are preset and ready to use "out-of-the-box". Custom front panels are also ava

Page 6

14 4.3 MOTOR WITH EXTERNAL FAN COOLING Most totally enclosed fan-cooled (TEFC) and open ventilated 3-phase AC induction motors will overheat if used

Page 7

15 If external fan cooling is provided, open ventilated motors can also achieve an extended speed range at full rated torque. A box fan or blower wit

Page 8 - (SHOWN WITH COVER REMOVED)

16 5 REMOVING AND INSTALLING THE COVER The cover must be removed to set up the drive. See Section 5.1, below, for instructions on removing the cover

Page 9 - Setting

17 FIGURE 5 COVER POSITIONED ON TOP OF CASE (All Wires Omitted for Clarity) 5.2 INSTALLING THE COVER After setting up the drive, install the cover

Page 10

18 6 INSTALLING THE SUPPLIED FORWARD-STOP-REVERSE SWITCH The Forward-Stop-Reverse Switch is used to change motor direction. The switch assembly easi

Page 11

19 7 SETTING SELECTABLE JUMPERS The drive has selectable jumpers which must be set before the drive can be used. For the location of jumpers, see Fi

Page 12

2 SAFETY WARNING Definition of Safety Warning Symbols Electrical Hazard Warning Symbol: Failure to observe this warning could result in electrical

Page 13

20 FIGURE 8 60 Hz AND 50 Hz MOTOR SELECTION 60 Hz Motor Operation (Factory Setting) (J1 Installed in "60 Hz" Position)(J2 Installed in &quo

Page 14

21 For 120 Hz output with 60 Hz motor, be sure Jumper J1 is set to the "60 Hz" position and set Jumper J2 to the "X2" position. F

Page 15

22 7.3.2 MANUAL START MODE The Manual Start Mode is used to manually start the drive or restart the drive (reset) if a fault has occurred. Remove

Page 16

23 8 MOUNTING Use the supplied mounting template to facilitate locating the holes to mount the drive. It is recommended that the drive be mounted ver

Page 17

24 9 RECONDITIONING THE BUS CAPACITORS This drive contains bus capacitors which must be reconditioned if the drive has been in storage for over one

Page 18

25 TABLE 4 TERMINAL BLOCK TB1 WIRE AND TIGHTENING TORQUE SPECIFICATIONS Copper Wire Size Range(Solid or Stranded*) Stripping Length Tightening Torq

Page 19

26 FIGURE 15 AC LINE INPUT, MOTOR, AND GROUND CONNECTIONS Drive Wired for 208/230 Volt AC Line Input (J3 Not Installed) (Factory Setting) Drive Wired

Page 20

27 11 HIGH VOLTAGE DIELECTRIC WITHSTAND TEST (HI-POT TEST) DESCRIPTION Testing agencies such as UL, CSA, etc., usually require that equipment underg

Page 21

28 FIGURE 16 TYPICAL HI-POT TEST SETUP 12 TRIMPOT ADJUSTMENTS The drive contains trimpots which are factory set for most applications. See Figure

Page 22

29 12.1 MINIMUM SPEED TRIMPOT (MIN) Sets the minimum speed of the motor. The MIN Trimpot is factory set to 0% of frequency setting. For a higher mi

Page 23

3 QUICK-START INSTRUCTIONS 1. REMOVE THE COVER: The cover must be removed to setup and wire the drive. See Section 5.1, on pages 16 and 17. 2. A

Page 24

30 12.4 DECELERATION TRIMPOT (DEC) Sets the amount of time for the motor to decelerate from full speed to zero speed. The DEC Trimpot is factory set

Page 25

31 12.6 CURRENT LIMIT TRIMPOT (CL) Motor Overload (I2t) with RMS Current Limit (CL) sets the current limit (overload), which limits the maximum curr

Page 26

32 13 DRIVE OPERATION 13.1 START-UP PROCEDURE After the drive has been properly setup (jumpers and trimpots set to the desired positions) and wiring

Page 27

33 TABLE 6 FAULT RECOVERY AND RESETTING THE DRIVE* (In Automatic Start Mode (Jumper Installed Onto CON1 (Factory Setting)) Fault Drive Recovery Unde

Page 28

34 14.1 ILLUMINATED ON/OFF AC LINE SWITCH The On/Off AC Line Switch will illuminate when the AC line is applied to the drive and the switch is in th

Page 29

35 – NOTES –

Page 30

KB Electronics, Inc. 12095 NW 39 Street, Coral Springs, FL 33065-2516 Phone: 954-346-4900; Fax: 954-346-3377 Outside Florida call Toll Free: 800-221

Page 31

4 TABLE OF CONTENTS Section Page 1 FAMILIARIZING YOURSELF WITH THE DRIVE ...7 2 ELECTRICAL RATINGS AN

Page 32

5 TABLE OF CONTENTS (CONTINUED) Section Page 10 ELECTRICAL CONNECTIONS...24

Page 33

6 TABLE OF CONTENTS (CONTINUED) Figure Page 1 Cover Layout ...

Page 34

7 1 FAMILIARIZING YOURSELF WITH THE DRIVE The drive has a factory installed On/Off AC Line Switch and a Main Speed Potentiometer. It also has provis

Page 35

8 FIGURE 2 DRIVE LAYOUT (SHOWN WITH COVER REMOVED)

Page 36

9 2 ELECTRICAL RATINGS AND SPECIFICATIONS TABLE 1 ELECTRICAL RATINGS AC Line Input Drive Output Net Wt. Model No. (Part No.) Maximum Horsepower (H